Millifactories

DIMENSIONS OF uPVC PIPES ACCORDING TO SSA 14-15/1976 EQUIVALENT TO DIN 8062

Nominal Outside diameter

mm

SERIES 1 SERIES 2 SERIES 3 SERIES 4 SERIES 5
2.5 KG/CM2 4 KG/CM2 6 KG/CM2 10 KG/CM2 16 KG/CM2

Nominal wall Thickness

mm

Nominal wall Thickness

mm

Nominal wall Thickness

mm

Nominal wall Thickness

mm

Nominal wall Thickness

mm

16 - - - - 1.2
20 - - - - 1.5
25 - - - 1.5 1.9
32 - - - 1.8 2.4
40 - - 1.8 1.9 3.0
50 - - 1.8 2.4 3.7
63 - - 1.9 3.0 4.7
75 - 1.8 2.2 3.6 5.6
90 - 1.8 2.7 4.3 6.7
110 1.8 2.2 3.2 5.3 8.2
125 1.8 2.5 3.7 6.0 9.3
140 1.8 2.80 4.1 6.7 10.4
160 1.8 3.2 4.7 7.7 11.9
200 1.8 4.0 5.9 9.6 14.9
225 1.8 4.5 6.6 10.8 16.7
250 2.0 4.9 7.3 11.9 18.6
280 2.3 5.5 8.2 13.4 20.8

315

2.5

6.2

9.2

15.0

23.4

355

2.9

7.0

10.4

16.9

26.3

400

3.2

7.9

11.7

19.1

29.7

NOTE: The nominal pressure is the maximum Sustained working pressure based on fluid at 23o Centigrade for operation at higher temperatures the working pressure should be reduced.